This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| manual_mcf-lw12terwp [2023/05/29 07:33] – external edit 127.0.0.1 | manual_mcf-lw12terwp [2025/02/28 12:30] (current) – [10 Declaration of conformity] supportadmin | ||
|---|---|---|---|
| Line 10: | Line 10: | ||
| * Do not dismantle or modify in any way. | * Do not dismantle or modify in any way. | ||
| - | * The device is not intended to be used as a reference sensor, and enginko | + | * The device is not intended to be used as a reference sensor, and Angel4Future |
| * Avoid mechanical stress | * Avoid mechanical stress | ||
| * Do not use any detergent or alcohol to clean the device. | * Do not use any detergent or alcohol to clean the device. | ||
| Line 150: | Line 150: | ||
| {{ : | {{ : | ||
| - | To perform the operation, you need a unique reset code that must be requested to enginko | + | To perform the operation, you need a unique reset code that must be requested to Angel4Future |
| | | ||
| {{ : | {{ : | ||
| Line 221: | Line 221: | ||
| {{ : | {{ : | ||
| - | The device exits factory activated with **NONE** mode. | + | The device exits factory activated with **OTAA ENGINKO** mode. |
| On request devices can be shipped aleady activated. | On request devices can be shipped aleady activated. | ||
| Line 289: | Line 289: | ||
| - | To bring back the sensor to factory default and reset the passwords, a reset code must be requested to enginko | + | To bring back the sensor to factory default and reset the passwords, a reset code must be requested to Angel4Future |
| ===== 6 Configuration file ===== | ===== 6 Configuration file ===== | ||
| - | WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to enginko). This is very useful especially in | + | WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to Angel4Future). This is very useful especially in |
| case of multiple devices configuration. | case of multiple devices configuration. | ||
| - | With " | + | With " |
| Line 327: | Line 327: | ||
| - | For details on files format please ask to enginko. | + | For details on files format please ask to Angel4Future. |
| ===== 7 LoRaWEB Tool ===== | ===== 7 LoRaWEB Tool ===== | ||
| - | enginko | + | Angel4Future |
| [[https:// | [[https:// | ||
| Line 357: | Line 357: | ||
| ===== 10 Declaration of conformity ===== | ===== 10 Declaration of conformity ===== | ||
| - | Hereby, enginko Srl declares that MCF-LW12TERWP complies with the essential requirements and other relevant provisions | + | Declarations |
| ===== 11 Contacts ===== | ===== 11 Contacts ===== | ||