| Line 10: | Line 10: | ||
| * Do not dismantle or modify in any way. | * Do not dismantle or modify in any way. | ||
| - | * The device is not intended to be used as a reference sensor, and enginko | + | * The device is not intended to be used as a reference sensor, and Angel4Future |
| * Avoid mechanical stress | * Avoid mechanical stress | ||
| * Do not use any detergent or alcohol to clean the device. | * Do not use any detergent or alcohol to clean the device. | ||
| === Disposal information for users === | === Disposal information for users === | ||
| - | {{: | + | {{: |
| The barred symbol of the rubbish bin shown on the equipment indicates that, at the end of its useful life, the product must be collected separately from other waste. | The barred symbol of the rubbish bin shown on the equipment indicates that, at the end of its useful life, the product must be collected separately from other waste. | ||
| Line 150: | Line 150: | ||
| {{ : | {{ : | ||
| - | To perform the operation, you need a unique reset code that must be requested to enginko | + | To perform the operation, you need a unique reset code that must be requested to Angel4Future |
| | | ||
| {{ : | {{ : | ||
| Line 158: | Line 158: | ||
| ==== 2.6 Firmware update==== | ==== 2.6 Firmware update==== | ||
| - | Save the firmware file (.FW) on the smartphone, and upload it with LoraTool App: | + | Download |
| + | |||
| + | {{ : | ||
| + | |||
| + | {{ : | ||
| + | |||
| + | {{ : | ||
| + | |||
| + | Update the sensor with LoRaTool: | ||
| {{ : | {{ : | ||
| Line 170: | Line 178: | ||
| ==== 3.1 Period ==== | ==== 3.1 Period ==== | ||
| - | Period is the interval (in minutes) between one measure and the next one. The sensor sends one measures for every transmission. | + | Period is the interval (in minutes) between one measure and the next one. The sensor sends three measures for every transmission. |
| - | Value can be between | + | Value can be between |
| Period interval can be set with App or with downlink command. | Period interval can be set with App or with downlink command. | ||
| Line 213: | Line 221: | ||
| {{ : | {{ : | ||
| - | The device exits factory activated with **NONE** mode. | + | The device exits factory activated with **OTAA ENGINKO** mode. |
| On request devices can be shipped aleady activated. | On request devices can be shipped aleady activated. | ||
| Note: in **OTAA** AppKey is write only, in reading the field will always be empty, even if set. | Note: in **OTAA** AppKey is write only, in reading the field will always be empty, even if set. | ||
| - | |||
| - | ----- | ||
| - | === Time sync == | ||
| - | |||
| - | {{: | ||
| - | |||
| - | Normally sensor asks for a time sync at every power on (uplink starting with 01) or once a week. | ||
| - | If no or wrong reply received it will retry after 1 hour. | ||
| - | |||
| - | |||
| - | If not handled in the right way can cause a unnecessary battery consumption (battery life < 2 years). | ||
| - | |||
| - | Please check chapter 2.1 of "DATA FRAME FORMAT" | ||
| - | |||
| - | |||
| - | |||
| - | |||
| - | |||
| - | |||
| - | |||
| ==== 4.2 Other settings ==== | ==== 4.2 Other settings ==== | ||
| Line 264: | Line 252: | ||
| If not handled in the right way can cause a unnecessary battery consumption (battery life < 2 years). | If not handled in the right way can cause a unnecessary battery consumption (battery life < 2 years). | ||
| - | Please check chapter 2.1 of "DATA FRAME FORMAT" document. | + | Please check chapter 2.1 [[data_frame_format| |
| ----- | ----- | ||
| Line 301: | Line 289: | ||
| - | To bring back the sensor to factory default and reset the passwords, a reset code must be requested to enginko | + | To bring back the sensor to factory default and reset the passwords, a reset code must be requested to Angel4Future |
| ===== 6 Configuration file ===== | ===== 6 Configuration file ===== | ||
| - | WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to enginko). This is very useful especially in | + | WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to Angel4Future). This is very useful especially in |
| case of multiple devices configuration. | case of multiple devices configuration. | ||
| - | With " | + | With " |
| Line 326: | Line 314: | ||
| When the sensor is approached, if one parameter is different from files, the APP will ask you if you want to overwrite. | When the sensor is approached, if one parameter is different from files, the APP will ask you if you want to overwrite. | ||
| - | XLS is prevailing on the XML, so if both files are enabled, if the DevEUI of the device matches one of the DevEUIS is in the XLS file, LoRa parameters will be setted from this one. | + | XLS is prevailing on the XML, so if both files are enabled, if the DevEUI of the device matches one of the DevEUIs |
| These configuration can be done in the in the Settings: | These configuration can be done in the in the Settings: | ||
| Line 339: | Line 327: | ||
| - | For details on files format please ask to enginko. | + | For details on files format please ask to Angel4Future. |
| ===== 7 LoRaWEB Tool ===== | ===== 7 LoRaWEB Tool ===== | ||
| - | enginko | + | Angel4Future |
| [[https:// | [[https:// | ||
| Line 369: | Line 357: | ||
| ===== 10 Declaration of conformity ===== | ===== 10 Declaration of conformity ===== | ||
| - | Hereby, enginko Srl declares that MCF-LW12TERWP complies with the essential requirements and other relevant provisions | + | Declarations |