This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| manual_mcf-lw06010 [2023/05/29 07:33] – external edit 127.0.0.1 | manual_mcf-lw06010 [2026/05/20 09:43] (current) – [11 Declaration of conformity] supportadmin | ||
|---|---|---|---|
| Line 139: | Line 139: | ||
| - | enginko | + | Angel4Future |
| Line 264: | Line 264: | ||
| {{ : | {{ : | ||
| - | The device exits factory activated with **NONE** mode. | + | The device exits factory activated with **OTAA ENGINKO** mode. |
| On request devices can be shipped aleady activated. | On request devices can be shipped aleady activated. | ||
| Line 308: | Line 308: | ||
| - | To bring back the sensor to factory default and reset the passwords, a reset code must be requested to enginko | + | To bring back the sensor to factory default and reset the passwords, a reset code must be requested to Angel4Future |
| ===== 8 General configuration file ===== | ===== 8 General configuration file ===== | ||
| - | WIth LoRaWEB is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to enginko). This is very useful especially in | + | WIth LoRaWEB is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to Angel4Future). This is very useful especially in |
| case of multiple devices configuration. | case of multiple devices configuration. | ||
| - | With " | + | With " |
| Line 340: | Line 340: | ||
| - | For details on files format please ask to enginko. | + | For details on files format please ask to Angel4Future. |
| ===== 9 Payload ===== | ===== 9 Payload ===== | ||
| Line 363: | Line 363: | ||
| - | ===== 11 Declaration of conformity ===== | + | ===== 11 Declaration of conformity ===== |
| + | |||
| + | Declarations of conformity are available from Angel4Future by sending a request email to sensors@enginko.com. | ||
| - | Hereby, enginko Srl declares that MCF-LW06010 complies with the essential requirements and other relevant provisions of Directive | ||
| ===== 12 FCC compliance for MCF-LW06010-US ===== | ===== 12 FCC compliance for MCF-LW06010-US ===== | ||
| Line 384: | Line 385: | ||
| ===== 13 Contacts ===== | ===== 13 Contacts ===== | ||
| - | **enginko Srl** \\ | + | **Angel4Future S.r.l.** \\ |
| - | Via Roma 3 I-28060 Sozzago | + | Via San Sabino 21 - 70042 MOLA DI BARI (BA) , ITALY \\ |
| - | T : +39 0321 15 93 088 \\ | + | T : +39 080 532 1796 \\ |
| - | E : info@enginko.com | + | E : info@angel4future.com \\ |
| - | PEC: enginkosrl@legalmail.it | + | W: |
| - | W: | + | |
| ---- | ---- | ||
| - | rev.0 | + | rev.1 |