This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| manual_egk_lw22twp00 [2023/10/02 11:59] – [2.3 Power ON/OFF] supportadmin | manual_egk_lw22twp00 [2026/05/20 09:44] (current) – [10 Declaration of conformity] supportadmin | ||
|---|---|---|---|
| Line 10: | Line 10: | ||
| * Do not dismantle or modify in any way. | * Do not dismantle or modify in any way. | ||
| - | * The device is not intended to be used as a reference sensor, and enginko | + | * The device is not intended to be used as a reference sensor, and Angel4Future |
| * Avoid mechanical stress | * Avoid mechanical stress | ||
| * Do not use any detergent or alcohol to clean the device. | * Do not use any detergent or alcohol to clean the device. | ||
| + | * Risk of explosion if the battery is replaced with an incorrect type. | ||
| + | * Risk of explosion if the battery pack is subjected to a short circuit. | ||
| + | * Risk of explosion if the battery is burned or placed near high heat sources. | ||
| + | * Risk of explosion if batteries are crushed, punctured or cut. | ||
| + | * Do not expose batteries to contact with liquid substances. | ||
| === Disposal information for users === | === Disposal information for users === | ||
| Line 39: | Line 44: | ||
| * Class A LoRaWAN® 1.0.2 , EU868 | * Class A LoRaWAN® 1.0.2 , EU868 | ||
| * OTAA/ABP activation | * OTAA/ABP activation | ||
| - | * Temperature -30 ÷ 70°C (typ. ±0.2°C within [0 ÷ 65°C], typ. ±0.5°C otherwise) | + | * Temperature -40 ÷ 65°C (typ. ±0.2°C within [0 ÷ 65°C], typ. ±0.5°C otherwise) |
| * Humidity 0% to 100% with following error @25°C: | * Humidity 0% to 100% with following error @25°C: | ||
| - | * | + | |
| - | - From 0% to 10% ±3% | + | - From 0% to 10% ±3% \\ - From 10% to 90% ±2% \\ - From 90% to 100% ±3% |
| - | * | + | |
| - | - From 10% to 90% ±2% | + | |
| - | * | + | |
| - | - From 90% to 100% ±3% | + | |
| * Pressure 300….1250hPa (±1hPa) | * Pressure 300….1250hPa (±1hPa) | ||
| * Embedded antenna (EGK-LW22TWP00) | * Embedded antenna (EGK-LW22TWP00) | ||
| Line 58: | Line 60: | ||
| * BLE 5.0 interface for configuration, | * BLE 5.0 interface for configuration, | ||
| * Remote configuration | * Remote configuration | ||
| - | * Storage temperature -30°C ÷ +80°C | + | * Storage temperature -40°C ÷ +80°C |
| - | * Working temperature -30°C ÷ +70°C | + | * Working temperature -40°C ÷ +65°C |
| * Dimensions: 98×58.5x39mm | * Dimensions: 98×58.5x39mm | ||
| * Protection grade: IP67 | * Protection grade: IP67 | ||
| * Weight: 95g | * Weight: 95g | ||
| + | |||
| ==== 2.2 Installation ==== | ==== 2.2 Installation ==== | ||
| Line 72: | Line 75: | ||
| === 2.2.1 Wall mount === | === 2.2.1 Wall mount === | ||
| - | For mounting onto wall, use the provided | + | For mounting onto wall, use the __optional__ wall mount bracket |
| {{: | {{: | ||
| Line 130: | Line 133: | ||
| This sensor contains lithium battery, which must be disposed of separately. | This sensor contains lithium battery, which must be disposed of separately. | ||
| - | EGK-LW22TWP00 is provided with a Li-SOCl2 | + | EGK-LW22TWP00 is provided with a replaceable |
| ^Code ^Description | ^Code ^Description | ||
| |EGK-1S2PCR | |EGK-1S2PCR | ||
| + | __Replacement battery only available from Angel4Future .__\\ | ||
| This is the estimated battery life (in **years**) in the worst conditions: | This is the estimated battery life (in **years**) in the worst conditions: | ||
| Line 143: | Line 147: | ||
| === 2.5.1 Battery replacement === | === 2.5.1 Battery replacement === | ||
| - | * remove the front panel of the sensor with a small screwdriver: | + | * remove the front panel of the sensor with a small hex key (for M2.5 bolts): |
| - | {{ : | + | {{ : |
| - | * remve the PCB batteries pack from the main board (PCB board is secured with two small screws): | + | * remove |
| - | {{ : | + | {{ : |
| - | {{ : | + | {{ : |
| * Place the new PCB batteries pack and put them in place with the screws: | * Place the new PCB batteries pack and put them in place with the screws: | ||
| - | {{ : | + | {{ : |
| - | < | + | |
| - | \\ | + | |
| - | + | ||
| - | </ | + | |
| __After the batteries replacement, | __After the batteries replacement, | ||
| - | {{ : | + | {{ : |
| - | To perform the operation, you need a unique reset code that must be requested to enginko | + | To perform the operation, you need a unique reset code that must be requested to Angel4Future |
| - | {{ : | + | {{ : |
| At the end of the procedure the battery level displays 100%. | At the end of the procedure the battery level displays 100%. | ||
| + | |||
| ==== 2.6 Firmware update ==== | ==== 2.6 Firmware update ==== | ||
| Line 226: | Line 228: | ||
| - **NONE**: sensor not activated | - **NONE**: sensor not activated | ||
| - **OTAA**: the JoinEUI and the AppKey not setted, must be written to the device; | - **OTAA**: the JoinEUI and the AppKey not setted, must be written to the device; | ||
| - | - **OTAA | + | - **OTAA |
| - **OTAA ENGINKO**: Over the air activation, fixed keys: JoinEUI = 904e915000000001, | - **OTAA ENGINKO**: Over the air activation, fixed keys: JoinEUI = 904e915000000001, | ||
| - **ABP**: requires writing to the device of NwkSkey, AppSkey, DevAddr. | - **ABP**: requires writing to the device of NwkSkey, AppSkey, DevAddr. | ||
| {{ : | {{ : | ||
| - | The device exits factory activated with **NONE** mode. On request devices can be shipped aleady activated. | + | The device exits factory activated with **OTAA ENGINKO** mode. On request devices can be shipped aleady activated. |
| Note: in **OTAA** | Note: in **OTAA** | ||
| Line 305: | Line 307: | ||
| {{ : | {{ : | ||
| - | To bring back the sensor to factory default and reset the passwords, a reset code must be requested to enginko | + | To bring back the sensor to factory default and reset the passwords, a reset code must be requested to Angel4Future |
| ===== 6 Configuration file ===== | ===== 6 Configuration file ===== | ||
| - | WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to enginko). This is very useful especially in case of multiple devices configuration. | + | WIth LoRa Tool App is possible to configure the device using an XML file, instead to manually adjust the parameters (for details about the file format please ask to Angel4Future |
| - | With " | + | With " |
| {{ : | {{ : | ||
| Line 338: | Line 340: | ||
| {{ : | {{ : | ||
| - | For details on files format please ask to enginko. | + | For details on files format please ask to Angel4Future |
| ===== 7 LoRaWEB Tool ===== | ===== 7 LoRaWEB Tool ===== | ||
| - | enginko | + | Angel4Future |
| [[https:// | [[https:// | ||
| Line 364: | Line 366: | ||
| ===== 10 Declaration of conformity ===== | ===== 10 Declaration of conformity ===== | ||
| - | Hereby, enginko Srl declares that EGK-LW22TWP00 complies with the essential requirements and other relevant provisions | + | Declarations |
| ===== 11 Contacts ===== | ===== 11 Contacts ===== | ||
| - | **enginko Srl** \\ Via Roma 3 I-28060 Sozzago | + | **Angel4Future S.r.l.** \\ |
| + | Via San Sabino 21 - 70042 MOLA DI BARI (BA) , ITALY \\ | ||
| + | T : +39 080 532 1796 \\ | ||
| - | E : info@enginko.com \\ PEC: enginkosrl@legalmail.it \\ W: enginko.com | + | E : info@angel4future.com \\ |
| + | W: | ||
| ---- | ---- | ||